            |  CT-3 | 
             CT-5 | 
          
           
             
                - High sensitivity , resolution 0.02 mT (0.2GS) 
                
 - Measuring the d.c. flux density and 0~600Hz 
                  a.c. flux density 
                
 - Measuring ransverse magnetic field (with CT3-1) 
                  axial magnetic field (with CT3-2) 
                
 - Discriminating N.S polarity of magnetic field 
                   
                
 - Power=220V 50Hz or R20(1.5V)x6 
 
                | 
             
                - Adopted the hall effect principal to measure 
                  d.c. flux density 
                
 - High precision constant current , Fine stability 
                
 - Fast measuring velocity , wide range 0.1m~2.5T 
                
 - Measuring transverse magnetic field (with CT5-1) 
                  axial magnetic field (with CT3-2) 
                
 - Power=220V 50Hz , 5W 
                
 - Size Weight=202 x 154 x 80mm , 2Kg 
 
                | 
          
           
            |   | 
              | 
          
           
            |  CT-7 | 
             CTS-27 | 
          
           
             
                - Range : 50mT / 100mT / 250mT / 500mT / 1T 
                
 - Accuracy : -2.5%~+2.5% / FS 
                
 - Hall probe : may exchange 
                
 - Polarity : N.N. may selected 
 
                | 
             
                - Range : 0.2T / 1T 
                
 - Accuracy : -1.0%~+1.0% Red + 1.0% FS 
                
 - Display : 3.5 LED 
                
 - Power : 9V (-10%~+10%) 
                
 - Size weight : 160 x 88 x 36mm , 325g 
                
 
                | 
          
           
            |   | 
              | 
          
           
            |  CST-7 | 
             CTS-24 | 
          
           
              
                
                  - Ranges : 0.001 / 0.01 / 0.1 / 1Wb(D.C) 
                  
 - Accuracy : -1%~+1% FS 
                  
 - Display : 1999LED 
                  
 - Peak reading hold accuracy : -1%~+1% FS (hold 
                    time < 10 Sec) 
                  
 - Power : 220V 50Hz 8W 
                  
 - Size Weight : 164 x 214 x 70mm 2Kg 
                  
 
                 
                | 
              
                
                  - Ranges : 0.1 / 1 / 10 d.c Flux density 
                  
 - Accuracy : -0.5%~+0.5% Red + 0.5% FS 
                  
 - Display : 1999 LED 
                  
 - Power : AC 220V 50Hz 8W 
                  
 - Size weight : 230 x 291 x 70mm , 2Kg 
                  
 
                 
                |